Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (5)
- (99)
- (8)
- (150)
- (9)
- (1)
- (8)
- (4)
- (6)
- (194)
- (1)
- (3)
- (22)
- (76)
- (185)
- (51)
- (126)
- (1)
- (1)
- (46)
- (14)
- (95)
- (18)
- (2)
- (22)
- (26)
- (6)
- (1)
- (4)
- (3)
- (4)
- (4)
- (11)
- (18)
- (8)
- (55)
- (145)
- (62)
- (3)
- (40)
- (225)
- (46)
- (18)
- (28)
- (8)
- (111)
- (31)
- (20)
- (55)
- (1)
- (32)
- (2)
- (13)
- (4)
- (1)
- (16)
- (1)
- (6)
- (25)
- (28)
- (1)
- (1)
- (2)
- (80)
- (5)
- (1)
- (1)
- (36)
- (1)
- (1)
- (810)
- (146)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (389)
- (309)
- (6)
- (3)
- (134)
- (633)
- (59)
Filtered Search Results
Cytiva Nucleus Membrane
Made from polycarbonate film, for precision analysis of track-etched manufacturing
| Type | Nucleus Membrane |
|---|---|
| Material | Polycarbonate |
| For Use With (Application) | Air Analysis, Bioassay, Cell Biology, Environmental Analysis, Epi-Fluorescence Microscopy, EPA Test, Fuel Test, Parasitology, and Underwater Microbiology |
MilliporeSigma™ Immobilon-NC Membranes, Triton-Free, 0.45 μm
Mixed Cellulose Esters, Surfactant-free
| Pore Size | 0.45 μm |
|---|---|
| Flow Rate | 60 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Blotting Membranes |
| Color | White |
| Material | MCE |
| For Use With (Application) | Clarification of fluids; Sterilizing filtration of tissue culture media, additives, antibiotics; Air monitoring; Particulate analysis; Particulate removal; Biological assays (receptor binding studies, TCA precipitates, etc.). |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Membrane Type | Plain |
Cytiva Life Sciences™ Sentino Membrane Dispenser Refill ME25
Gridded, ME25 mixed cellulose ester membranes.
MilliporeSigma™ Fluoropore™ Membrane Filter, Pore Size: 5 μm
Unlike fibrous filter media that trap particles in their matrix, Fluoropore™ membranes collect particles on their surface. For use in airborne particle monitoring applications.
| Pore Size | 5.0 μm |
|---|---|
| Flow Rate | 122 mL/min x cm2 |
| Wettability | Hydrophobic |
| Type | Screen Filter |
| Material (Membrane) | Fluoropore |
| Material | PTFE |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophobic |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
Cytiva™ Whatman™ NC45 Nitrocellulose Filtration Membranes
Whatman™ NC45 Nitrocellulose Membrane Filters are known for higher strength and flexibility, low extractables, and narrow pore size distribution. They are recommended for routine applications and are manufactured under strictly controlled conditions.
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.45 μm, Gridded
Mixed cellulose esters (MCE) membrane, hydrophilic
Cytiva Whatman Cyclopore Polycarbonate Membrane
Featuring sharp cut-off and reproducible microfiltration characteristics of track-etched membrane filters
| Material | Polycarbonate |
|---|
MilliporeSigma™ Fluoropore™ Membrane Filters, 0.5 μm
Hydrophobic membrane with laminated backing for easier handling
| Pore Size | 0.45 μm |
|---|---|
| Bubble Point | 7 psi |
| Flow Rate | 60 mL/min x cm2 |
| Wettability | Hydrophobic |
| Type | Filter Membranes |
| Color | White |
| Material | PTFE |
| Hydrophobicity | Hydrophobic |
| For Use With (Application) | Clarification of Acids, Bases and Solvents; Clarification of Alcohol Solutions; UV Spectroscopy. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 8.0 L/min/cm2 |
Cytiva Whatman™ Nuclepore™ Hydrophilic Membrane
A highly defined pore size cutoff in the sub-micron range enables particle deformity measurements, and the capture of extremely small particles
| Type | Track Etched Hydrophilic Membrane Filters |
|---|---|
| Shape | Circle |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Bioassays, Cell Biology and Environment Analysis |
| Membrane Type | Polycarbonate Film Track-Etched (PFTE) |
Cytiva Whatman™ 0.8 μm Pore Size (ME 27) Mixed Cellulose Ester Membranes, White/Black Grid
Whatman™ (ME 27) Mixed Cellulose Ester Membranes, White/Black Grid are particularly effective in applications requiring higher flow rates and larger volume filtration. Supplied with clearly defined grid lines at regularly spaced intervals to assist in microbiological colony counting.
| Pore Size | 0.8 μm |
|---|---|
| Diameter (English) | 1.85 in. |
| Material (Membrane) | ME 27 |
| Color | White |
| Grid Color | Black |
| Quantity | 100 Pk. |
| Material | MCE |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Sterility | Sterile |
| Thickness (Metric) | 140 μm |
| Bubble Point | 1.3 bar |
| Flow Rate | 2.8 sec./100 mL/12.5 cm2 (at Δp = 0.9 bar) |
| Diameter (Metric) | 47 mm |
| Thickness (English) | 0.006 in. |
| Autoclavable | Autoclavable |
| Size (Metric) Grid | 3.1 mm |
| Gas Flow Rate | 11.6 sec./100 mL (at Δp = 3 mbar) |
MilliporeSigma™ Fluoropore™ Membrane Filter for Filtration of Solvents
The Fluoropore™ membrane filter is a hydrophobic, polytetrafluoroethylene (PTFE) polymer membrane bonded to a high density polyethylene support to improve filter handling characteristics for normal applications.
MilliporeSigma™ Isopore™ Membrane Filters, 0.6 μm
Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of pore sizes/flow rates, diameters and colors.
| Pore Size | 0.6 μm |
|---|---|
| Color | White |
| No. per Case | 100Pack |
| Quantity | 100/Pk. |
| Material | Polycarbonate |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Air Analysis; Cell Biology; Cell Culture; Bioassays; Cytology; Environmental Analysis; Epifluorescence. |
| Sterility | Non-sterile |
| Bubble Point | 8.5 psi |
| Flow Rate | Avg. 43 mL/min x cm2 (typical results (at 10 psi);62 mL/min x cm2/psi) |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Filter Type | Screen Filter |
| Autoclavable | Not Autoclavable |
| Gas Flow Rate | 10.0 L/min/cm2 |
Cytiva Whatman™ Regenerated Cellulose Membranes: Grade RC 55
Consists of pure cellulose without any wetting agents.
| Thickness (Metric) | 75 μm |
|---|---|
| Material | Regenerated Cellulose |
| Hydrophobicity | Hydrophilic |
Sartorius Hydrophobic edged Sterile Cellulose Nitrate and Acetate Membrane Filters
Membrane Filters for Colony Counting and Sterility Testing - Cellulose nitrate (cellulose ester), Cellulose acetate and regenerated Cellulose, hydrophobic edged, individually, sterile packaged
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Color | White |
| Grid Color | Black |
| Quantity | 100/Pk. |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophobic |
| Sterility | Sterile |
Sartorius Polycarbonate Track Etch Membrane Filters
Manufactured from high grade polycarbonate film using track-etch technology.
| Thickness (Metric) | 23 to 27 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Polycarbonate |
| Quantity | 100/Pk. |
| Material | PCTE |
| Filter Type | Membrane Filter |
| For Use With (Application) | Particulate analysis; epifluorescence miroscopy; fluid clarification; cytology; cell biology; bioassays; water microbiology; environmental analysis. |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |